Refine your search:     
Report No.
 - 
Search Results: Records 1-6 displayed on this page of 6
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Status of study of long-term assessment of transport of radioactive contaminants in the environment of Fukushima (FY2018) (Translated document)

Nagao, Fumiya; Niizato, Tadafumi; Sasaki, Yoshito; Ito, Satomi; Watanabe, Takayoshi; Dohi, Terumi; Nakanishi, Takahiro; Sakuma, Kazuyuki; Hagiwara, Hiroki; Funaki, Hironori; et al.

JAEA-Research 2020-007, 249 Pages, 2020/10

JAEA-Research-2020-007.pdf:15.83MB

The accident of the Fukushima Daiichi Nuclear Power Station, Tokyo Electric Power Company Holdings, Inc. occurred due to the Great East Japan Earthquake, Sanriku offshore earthquake, of 9.0 magnitude and the accompanying tsunami. As a result, large amount of radioactive materials was released into the environment. Under these circumstances, Japan Atomic Energy Agency (JAEA) has been conducting "Long-term Assessment of Transport of Radioactive Contaminants in the Environment of Fukushima" concerning radioactive materials released in environment, especially migration behavior of radioactive cesium since November 2012. This report is a summary of the research results that have been obtained in environmental dynamics research conducted by JAEA in Fukushima Prefecture.

Journal Articles

Sensitivity study on forest fire breakout and propagation conditions for forest fire hazard curve evaluations

Okano, Yasushi; Yamano, Hidemasa

Mechanical Engineering Journal (Internet), 4(3), p.16-00517_1 - 16-00517_10, 2017/06

A sensitivity study on forest fire hazard curves was performed. The probability fluctuation on forest fire breakout time affects the reaction intensity and the fireline intensity around 4% and 14% respectively. The probability fluctuation on forest fire breakout points affects the hazard curve frequency around +70% to -40%. The probability fluctuation due to forest firefighting operation only affects the frequency of the hazard curves, but not the intensity. The hazard curves without the effect of firefighting remarkably increase around 40 to 80 times in frequency in comparison with those with considering the forest firefighting operation effect outside the plant. This study indicated that the most significant factor in the forest fire hazard risk is whether the forest firefighting operation outside the plant is expected before the forest fire arrival at the plant.

Journal Articles

Event sequence analyses of a forest fire heat effect on a sodium-cooled fast reactor for an external hazard PRA methodology development

Okano, Yasushi; Yamano, Hidemasa

Proceedings of 10th Japan-Korea Symposium on Nuclear Thermal Hydraulics and Safety (NTHAS-10) (USB Flash Drive), 9 Pages, 2016/11

This paper deals with an event sequence by forest fire heat effect on a decay heat removal function of a sodium-cooled fast reactor. Related to the potential vulnerability, an event scenario was developed using conservative assumptions. An event tree was developed with an initiating event of the loss of off-site power, and the headings are related to "external diesel fuel tanks", "emergency diesel generator and its auxiliary system", "alternative cooling system and its power source", and "decay heat air cooler". A failure probability on each heading was given from a fragility curve as a function of reaction intensity or by assumptions based on conservative models. A core damage frequency, under the conditional of the loss of off-site power, was conservatively evaluated around 10$$^{-7}$$/year. A key heading in the event tree with large effect on the frequency is the intactness of the external diesel fuel tanks.

Journal Articles

Hazard curve evaluation method development for a forest fire as an external hazard on nuclear power plants

Okano, Yasushi; Yamano, Hidemasa

Journal of Nuclear Science and Technology, 53(8), p.1224 - 1234, 2016/08

 Times Cited Count:4 Percentile:36.53(Nuclear Science & Technology)

A method to obtain a hazard curve of a forest fire was developed. The method has four steps: a logic tree formulation, a response surface evaluation, a Monte Carlo simulation, and an annual exceedance frequency calculation. The logic tree consists domains of forest fire breakout and spread conditions, weather conditions, vegetation conditions, and forest fire simulation conditions. The new method was applied to evaluate hazard curves of a reaction intensity and a fireline intensity for a typical location around a sodium-cooled fast reactor in Japan.

JAEA Reports

Impact assessment of the forest fires on Oarai Research and Development Center Waste Treatment Facility

Shimomura, Yusuke; Hanari, Akira*; Sato, Isamu*; Kitamura, Ryoichi

JAEA-Technology 2015-062, 47 Pages, 2016/03

JAEA-Technology-2015-062.pdf:1.85MB

In response to new standards for regulating waste management facilities, it was carried out impact assessment of forest fires on the waste management facilities existed in Oarai Research and Development Center of Japan Atomic Energy Agency. At first, a fire spread scenario of forest fires was assumed. The intensity of forest fires was evaluated from field surveys, forest fire evaluation models and so on. As models of forest fire intensity evaluation, Rothermel Model and Canadian Forest Fire Behavior Prediction (FBP) System were used. Impact assessment of radiant heat to the facilities was carried out, and temperature change of outer walls for the assumed forest fires was estimated. The outer wall temperature of facilities was estimated around 160$$^{circ}$$C at the maximum, it was revealed that it doesn't reach allowable temperature limit. Consequently, it doesn't influence the strength of concrete. In addition, a probability of fire breach was estimated to be about 20%. This report illustrates an example of evaluation of forest fires for the new regulatory standards through impact assessment of the forest fires on the waste management facilities.

Journal Articles

Development of risk assessment methodology of decay heat removal function against external hazards for sodium-cooled fast reactors, 3; Numerical simulations of forest fire spread and smoke transport as an external hazard assessment methodology development

Okano, Yasushi; Yamano, Hidemasa

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 9 Pages, 2015/05

Numerical simulations of forest fire propagation and smoke transport were performed with sensibility studies to weather conditions, and the effect by the smoke on the air filter was quantitatively evaluated. Forest fire propagation simulations were performed using FARSITE code. A temporal increase of a forest fire spread area, a position of the frontal fireline, "reaction intensity" and "frontal fireline intensity" are obtained and used for the smoke transport simulations by ALOFT-FT where spatial distribution of PM2.5 and PM10 are evaluated. The total amount of particle matter at the air filter at the nuclear power plant is around several hundred grams per m$$^{2}$$ which is well below the operational limit of the air filter of 15 kg/m$$^{2}$$.

6 (Records 1-6 displayed on this page)